My Research Group at WCU
Dr. Zhiheng Song, Postdoctoral Researcher
Nick Gray - Physics Major, Senior: Photoluminescence & Time Correlated Single Photon Counting
Gloria Zavala - Physics Major, Senior: Photoluminescence & Microscopy
Bhavana Palla - Physics Major, Senior: Ultrafast Pump-Probe Spectroscopy
Connor Strine - Physics Major, Senior: Quantum Optics
Angel Flowers - Physics Major, Sophomore: Figuring stuff out
Nick Gray - Physics Major, Senior: Photoluminescence & Time Correlated Single Photon Counting
Gloria Zavala - Physics Major, Senior: Photoluminescence & Microscopy
Bhavana Palla - Physics Major, Senior: Ultrafast Pump-Probe Spectroscopy
Connor Strine - Physics Major, Senior: Quantum Optics
Angel Flowers - Physics Major, Sophomore: Figuring stuff out
My students are active in and outside of the lab. They participate in our K-12 STEM outreach events and even assist with higher level workshops, which as an ALPHA Immersion Workshop on the THORLABS Quantum Optics Kit
Available Research Equipment
The Mitchell lab is currently equipped with five main capabilities:
Low-Temperature Optical Spectroscopy:
To excite the samples, we have a Kimmon Koha 325nm He-Cd laser, a Thorlabs Q-switched ns pulsed laser at 405 nm, a Leukos Samba supercontinuum laser, an Explorer-ONE Q-switched ns pulsed laser at 349 nm, and various Thorlabs CW diode lasers at 405 nm, 488 nm, 532 nm, 640 nm and 800 nm. For full wavelength tunability, we have an air-cooled Quantum Light Instruments Q-Tune laser. This laser consists of a Nd:YAG pumped OPO system. The emission can be tuned from 210 nm to 2200 nm with a linewidth of less than 6 cm-1. The emission is pulsed at 33 Hz with a pulse width of ~5 ns with >1 mJ pulse energy across the spectrum. For fs-pulsed excitation, we have an Ultrafast Systems HYPERION + APOLLO-Y. The HYPERION produces ~290 fs pulses with variable repetition rates ranging from single-shot to 200 kHz and pumps the APOLLO-Y OPA with a deep UV extension. This system can produce wavelengths from 266 nm to 1300 nm.
Photoluminescence and Time-Correlated Single Photon Counting
UV/VIS – An Ocean Optics spectrometer (USB4000), Thorlabs Compact Spectrometer, and a fan-cooled Princeton Instruments PIXIS-400 CCD cameras are used for UV/VIS detection. The PIXIS Camera is mounted to an HRS-300 monochromator. Various optics and a fiber-based microscope to excite and collect emissions from samples. Optical choppers, PMTs and Si-APDs (Excelitas), and lock-in amplifiers can be used for temporal dynamic studies.
NIR - We have a Horiba iHR-320 monochromator with two gratings blazed at 1000 nm and 1500 nm. A liquid nitrogen-cooled Symphony II InGaAs array is attached to one exit port and can measure light from 900 nm – 1650 nm with a QE above 80%. For temporal studies, the other exit port can be connected to a two-channel superconducting nanowire single photon detector (Quantum Opus), which has a detection efficiency of > 90% with less than 25 counts of dark noise. This system can be used on its own for correlation studies in the Hanbury-Brown-Twiss configuration.
Both time-resolved systems utilize a time-correlator (Swabian Time Tagger-20) for ps detection and an oscilloscope for longer collection intervals. We also have a Montana Instruments Cryostation s50, which allows samples to be cooled to ~10K. This is a closed-cycle cryostat, and so liquid helium will not need to be purchased to perform temperature-dependent measurements. A magneto-optical add-on module from Montana Instruments can be used to apply magnetic fields of up to 1.4 T to the samples while allowing them to be cooled from 10 K – 295 K.
Ultrafast Transient Absorption Spectroscopy – The Mitchell Lab has an ultrafast pump-probe laser spectroscopy system by Ultrafast Systems (NSF MRI Award #2319135). A tunable femtosecond laser system (HYPERION + APOLLO-Y) are used as the excitation (pump) source and to produce the white light (probe) beam within a HELIOS TAS system. The HELIOS has two continuum probe generators, 350 - 520 nm (UV) and 480-950 nm (VIS). The spectral range of the detector is 350 nm – 950 nm, with a spectra resolution of ~2 nm. The delay line has a step size of 15 fs with a maximum window of 8 ns. The HYPERION produces ~290 fs pulses with variable repetition rates ranging from single-shot to 200 kHz. This laser pumps an optical parametric amplifier (OPA) with a deep UV extension, which can produce wavelengths from 266 nm to 1300 nm. This wavelength range can be used to probe a large variety of solid-state, soft-matter, and organic materials.
Low-Temperature Optical Spectroscopy:
To excite the samples, we have a Kimmon Koha 325nm He-Cd laser, a Thorlabs Q-switched ns pulsed laser at 405 nm, a Leukos Samba supercontinuum laser, an Explorer-ONE Q-switched ns pulsed laser at 349 nm, and various Thorlabs CW diode lasers at 405 nm, 488 nm, 532 nm, 640 nm and 800 nm. For full wavelength tunability, we have an air-cooled Quantum Light Instruments Q-Tune laser. This laser consists of a Nd:YAG pumped OPO system. The emission can be tuned from 210 nm to 2200 nm with a linewidth of less than 6 cm-1. The emission is pulsed at 33 Hz with a pulse width of ~5 ns with >1 mJ pulse energy across the spectrum. For fs-pulsed excitation, we have an Ultrafast Systems HYPERION + APOLLO-Y. The HYPERION produces ~290 fs pulses with variable repetition rates ranging from single-shot to 200 kHz and pumps the APOLLO-Y OPA with a deep UV extension. This system can produce wavelengths from 266 nm to 1300 nm.
Photoluminescence and Time-Correlated Single Photon Counting
UV/VIS – An Ocean Optics spectrometer (USB4000), Thorlabs Compact Spectrometer, and a fan-cooled Princeton Instruments PIXIS-400 CCD cameras are used for UV/VIS detection. The PIXIS Camera is mounted to an HRS-300 monochromator. Various optics and a fiber-based microscope to excite and collect emissions from samples. Optical choppers, PMTs and Si-APDs (Excelitas), and lock-in amplifiers can be used for temporal dynamic studies.
NIR - We have a Horiba iHR-320 monochromator with two gratings blazed at 1000 nm and 1500 nm. A liquid nitrogen-cooled Symphony II InGaAs array is attached to one exit port and can measure light from 900 nm – 1650 nm with a QE above 80%. For temporal studies, the other exit port can be connected to a two-channel superconducting nanowire single photon detector (Quantum Opus), which has a detection efficiency of > 90% with less than 25 counts of dark noise. This system can be used on its own for correlation studies in the Hanbury-Brown-Twiss configuration.
Both time-resolved systems utilize a time-correlator (Swabian Time Tagger-20) for ps detection and an oscilloscope for longer collection intervals. We also have a Montana Instruments Cryostation s50, which allows samples to be cooled to ~10K. This is a closed-cycle cryostat, and so liquid helium will not need to be purchased to perform temperature-dependent measurements. A magneto-optical add-on module from Montana Instruments can be used to apply magnetic fields of up to 1.4 T to the samples while allowing them to be cooled from 10 K – 295 K.
Ultrafast Transient Absorption Spectroscopy – The Mitchell Lab has an ultrafast pump-probe laser spectroscopy system by Ultrafast Systems (NSF MRI Award #2319135). A tunable femtosecond laser system (HYPERION + APOLLO-Y) are used as the excitation (pump) source and to produce the white light (probe) beam within a HELIOS TAS system. The HELIOS has two continuum probe generators, 350 - 520 nm (UV) and 480-950 nm (VIS). The spectral range of the detector is 350 nm – 950 nm, with a spectra resolution of ~2 nm. The delay line has a step size of 15 fs with a maximum window of 8 ns. The HYPERION produces ~290 fs pulses with variable repetition rates ranging from single-shot to 200 kHz. This laser pumps an optical parametric amplifier (OPA) with a deep UV extension, which can produce wavelengths from 266 nm to 1300 nm. This wavelength range can be used to probe a large variety of solid-state, soft-matter, and organic materials.
Low-Temperature Electroluminescence Spectroscopy: A probe station is available with 5μm probe tips. Current sources include a standard DC power supply, and a Thorlabs DC2200 modulated current diode driver. Light from LEDs is collected using a home-built fiber-based microscope that sends the signal to an Ocean Optics USB4000 spectrometer with ~1 nm spectral resolution from 400nm - 900nm. Samples can be mounted inside the Montana Instruments s50 cryostat and controlled through the vacuum-sealed electrical ports.
Surface Imaging and Other Characterization:
Sample surfaces can be imaged and analyzed using a Zygo ZeGage™ 3D Optical Surface Profiler when micron resolution is needed and/or a Hitachi Atomic Force Microscope (AFM5100N) when nano-scale resolution is needed. In addition, the AFM has a software upgrade that allows for carrier transport measurements along sample surfaces. In addition, for thin film thickness and refractive index characterization, we have a FilmSense FS-XY150 Multi-Wavelength Ellipsometer, which has six wavelengths for ellipsometric data (405, 450, 525, 660, 850, 950 nm).
Surface Imaging and Other Characterization:
Sample surfaces can be imaged and analyzed using a Zygo ZeGage™ 3D Optical Surface Profiler when micron resolution is needed and/or a Hitachi Atomic Force Microscope (AFM5100N) when nano-scale resolution is needed. In addition, the AFM has a software upgrade that allows for carrier transport measurements along sample surfaces. In addition, for thin film thickness and refractive index characterization, we have a FilmSense FS-XY150 Multi-Wavelength Ellipsometer, which has six wavelengths for ellipsometric data (405, 450, 525, 660, 850, 950 nm).
Mitchell Lab Undergraduate Training Room
The Center for Nanomaterials Undergraduate Research Training Lab, maintained by the Mitchell Research Group, is a dedicated space to providing hands-on training for students in areas such as pump-probe spectroscopy, microscopy, and state-of-the-art materials simulation software.
THORLABS Spectroscopy – Thorlabs' Spectrometer Educational Kit includes the components to build a grating-based or dispersing prism-based spectrometer. The Czerny-Turner Extension Kit includes additional components that allow students to build a scanning spectrometer with Czerny-Turner geometry.
THORLABS Microscopy Course – The Optical Microscopy Course Kit contains components, documentation, and software for a full undergraduate course in optical microscopy. During the course, students build and operate a modular microscope in order to learn about image formation, resolution, aberrations, conjugate planes, and more. The course also introduces students to several imaging techniques, such as darkfield, phase contrast, and fluorescence microscopy.
THORLABS Pump-Probe Spectroscopy – This Time-Resolved Absorption Spectroscopy (TRAS) Educational Kit explores depopulation and charge transfer dynamics in the nanosecond regime using transient absorption (TA) spectroscopy. This technique uses transmission measurements to determine the change in absorbance of a sample after excitation by light. Designed for a master's level laboratory course, this kit builds the foundation to understand more complex femtosecond spectroscopy techniques commonly used in research. This kit measures the TA signal in zinc-tetraphenylporphyrin (ZnTPP), which is a molecule often used in light harvesting applications to study excited state population dynamics. Also investigated is the influence of fullerene C70 on the depopulation speed, or decay time. In addition to performing the experiments supported by the kit, students also have the opportunity to practice standard optical alignment techniques and explore how misalignments in an optical setup can affect the detected TA signal.
THORLABS Optical Tweezers – Optical tweezers, also known as optical traps, move and manipulate small particles using only a beam of light. A focused laser beam is used to exert forces on electrically uncharged particles with sizes from 1 to 10 µm, allowing the particles to be trapped, moved, and manipulated. This optical tweezers lab kit features an easy-to-construct optical path and sample positioning stage, a visible laser source, and a camera system for easy demonstration.
Raman Spectroscopy - A compact turn-key probe-based system operating at 785 nm is available from Wasatch Photonics. This system is used to train students on the concepts of vibrational spectroscopy as well as for research projects.
Computational Materials Science - The materials modeling software, Vienna Ab initio Simulation Package (VASP), and the computational chemistry software program Gaussian16 are available on these computers for electronic structure calculations of finite and periodic systems. Crystal Maker software is also available. These are housed on a Lenovo ThinkStation PX Workstation with a 4.10 GHz Intel® Xeon® Gold 5420+ Processor, NVIDIA® RTX™ A5500 24GB GDDR6 graphics card, 256 GB DDR5-4400MHz (RDIMM, ECC) - (16 x 16 GB) of memory and 8 TB of storage.
THORLABS Spectroscopy – Thorlabs' Spectrometer Educational Kit includes the components to build a grating-based or dispersing prism-based spectrometer. The Czerny-Turner Extension Kit includes additional components that allow students to build a scanning spectrometer with Czerny-Turner geometry.
THORLABS Microscopy Course – The Optical Microscopy Course Kit contains components, documentation, and software for a full undergraduate course in optical microscopy. During the course, students build and operate a modular microscope in order to learn about image formation, resolution, aberrations, conjugate planes, and more. The course also introduces students to several imaging techniques, such as darkfield, phase contrast, and fluorescence microscopy.
THORLABS Pump-Probe Spectroscopy – This Time-Resolved Absorption Spectroscopy (TRAS) Educational Kit explores depopulation and charge transfer dynamics in the nanosecond regime using transient absorption (TA) spectroscopy. This technique uses transmission measurements to determine the change in absorbance of a sample after excitation by light. Designed for a master's level laboratory course, this kit builds the foundation to understand more complex femtosecond spectroscopy techniques commonly used in research. This kit measures the TA signal in zinc-tetraphenylporphyrin (ZnTPP), which is a molecule often used in light harvesting applications to study excited state population dynamics. Also investigated is the influence of fullerene C70 on the depopulation speed, or decay time. In addition to performing the experiments supported by the kit, students also have the opportunity to practice standard optical alignment techniques and explore how misalignments in an optical setup can affect the detected TA signal.
THORLABS Optical Tweezers – Optical tweezers, also known as optical traps, move and manipulate small particles using only a beam of light. A focused laser beam is used to exert forces on electrically uncharged particles with sizes from 1 to 10 µm, allowing the particles to be trapped, moved, and manipulated. This optical tweezers lab kit features an easy-to-construct optical path and sample positioning stage, a visible laser source, and a camera system for easy demonstration.
Raman Spectroscopy - A compact turn-key probe-based system operating at 785 nm is available from Wasatch Photonics. This system is used to train students on the concepts of vibrational spectroscopy as well as for research projects.
Computational Materials Science - The materials modeling software, Vienna Ab initio Simulation Package (VASP), and the computational chemistry software program Gaussian16 are available on these computers for electronic structure calculations of finite and periodic systems. Crystal Maker software is also available. These are housed on a Lenovo ThinkStation PX Workstation with a 4.10 GHz Intel® Xeon® Gold 5420+ Processor, NVIDIA® RTX™ A5500 24GB GDDR6 graphics card, 256 GB DDR5-4400MHz (RDIMM, ECC) - (16 x 16 GB) of memory and 8 TB of storage.

